TECHNICAL
DATA
Quantum Walling & ComfortFrame IWI
System Elements
High Performance Laminates
MotionFrame Compression System
OmniLink or OmniLink-Q LSF Connectors
50mm C Profile Studs
50mm U Profile Base Track
Technical Note: OmniLink LSF connectors subject to system type and specification
Technical Note: 50mm/70mm/90mm profiles subject to laminate depth/performance requirements
Acoustics
59dB
Technical Note: Subject to material thicknesses and total laminate depth
Thermal
U-Values: 0.28 - 0.36 w/m2k
Technical Note: Subject to material thicknesses and total laminate depth
Impact Resistance
Severe Duty
Loading
58kg per fixing
Technical Note: Subject to load distance and screw centres
Technical Note: Subject to laminate specification
System Deflection
+/- 25mm at base as standard
Technical Note: System designs available for variations to standard deflection specification
Fire Rating
30 to 105 minutes
Fire Detailing
Moisture
High Resistance
Technical Note: Subject to System Laminate selection
Standard System Finishing
Inter Panel Joint Width: 3mm
Joint Profile: 1mm chamfered edge
Joint Filler: Standard Products
Final Finish: Direct application of primer and paints or wallpapers
Panel Dimensions and Weights
Optimum for 2 Man Manual Handling (40Kg):
2400mm x 580mm
Technical Note: Subject to System Laminate selection
Available panel sizes:
Panels available in all sizes to suit the individual project
OmniLink LSF connectors
OmniLink
Material
3mm Zintec
Movement
Omnidirectional
OmniLink-Q
Materials
3mm Zintec
Polymer
Movement
Low Friction Omnidirectional
Fire Testing
Retrofit conditions
As per Q-Wall Installation to EN1364 & EN1363
(Q-Wall 75P+ & Q-Wall 175P+ Systems)